Skip to content
FSG Stair

Validation

The program has a validation tab you can run yourself: each test shows the program value, the reference and the error.

TestError
Fixed–fixed beam: support M = wL²/12, span M = wL²/24, deflection with shear0.000%
Cantilever: deflection PL³/3EI + PL/GAs and moment PL0.000%
90° curved cantilever: deflection, torsion and bending at the support0.000–0.02%
Simply supported inclined flight: M = w·Lh²/8, reaction and deflection with cos α0.000%
NBR 6118 Table 8.1: Eci and Ecs from C20 to C500.000%
Linearity and superposition of load cases0.000%
Natural frequencies of simply supported and cantilever beams0.2–0.8%
180° helical stair (Vasconcelos, 2010): N, shears, torsion and lateral bending1.8–5.7%
Helix symmetry under symmetric load (T, Vz and Mz vanish at mid-span)≈ 10⁻¹³
Equilibrium (Σ reactions vs. total load) in every model0.00%

Real reference projects

11 stairs from real projects — helical, folded plate, curved, S-shaped with a central beam, and with cantilevered steps — were rebuilt in the program's engine, with equilibrium closing to 0.00% for every load case. The study drove features such as line-hinged supports, loads on the true area and guardrails as line loads. With the same supports and loads, the program's parametric shell differs from those rebuilt models by 0.5% to 8%, mainly due to the coarser meshes of the original models.

Documented theory

The program's Theory tab describes the formulations: Timoshenko stiffness matrix, local axes, equivalent loads, MITC4 shell, the criteria of each code and modal analysis.

FSG Stair automates analysis, design and detailing. Technical responsibility and final checking always remain with the engineer of record.